Medical Instrucments for Clinical! ! Disposable Non-Electric Biopsy Forceps

Type: Endoscopic Accessories
Material: Plastic, Stainless Steel, Nitinol
Ethylene Oxide Sterilization: Eo Sterilization
Quality Guarantee Period: Two Years
Group: Adult or Pediatrics
Logo Printing: Customerization, OEM
Samples:
US$ 1/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

Contact Supplier

Gold Member Since 2007

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
JHY-FB
Package Material
PE+Tyvek(1059b), Corrugated Carton
Application
Minimally Invasive Surgery, Ercp, ESD
Transport Package
1PC/Bag
Specification
Disposable Biopsy Forceps
Trademark
JIUHONG
Origin
Changzhou, Jiangsu, China
HS Code
9018909010
Production Capacity
2million PCS/Year

Product Description

Medical Instrucments for Clinical! ! Disposable Non-Electric Biopsy Forceps

Intended use
Tissue sampling in digestive and respiratory tracts. ( Disposable Biopsy Forceps - FB )


Features
*Special sharpness treatment on cups, easier to sample.
*Innovational 4-bar linkage design, offering an excellent rigidness.
*Tiny interval between jaws, large occlusal force and outstanding fitness.
*Smooth jaws, effectively decrease the friction to working channel.
*Standard cups design with proper sampling capacity, small tissue harm.

Material Table
      Component                      Material          Standard
Spike X5CrNi18-10, X5CrNiCuNb16-4 EN10088-1-2005
Jaw X5CrNi18-8, X5CrNiCuNb16-4 EN10088-1-2005
Spring Sheath                X5CrNi18-10 EN10088-1-2005
Pulling Wire                X5CrNi18-10 EN10088-1-2005
Slider                     ABS ISO2580-1-2002
Handle                     ABS ISO2580-1-2002
Protective Sleeve                     TPE ASTM D5927-2009
Coating                      PE ASTM D7436-2012

Specifications
Model  Jaw O.D.
(mm)
Working Length
(mm)
Endoscope Channel
(mm)
Characteristics
JHY-FB-18-105-O-P 1.8 1050 ≥2.0 without spike, coated, with standard oval cup.
JHY-FB-18-160-O-O 1.8 1600 ≥2.0 without spike, uncoated, with standard oval cup.
JHY-FB-23-160-W-O 2.3 1600 ≥2.8 with spike, uncoated, with standard oval cup.
JHY-FB-23-180-O-O 2.3 1800 ≥2.8 without spike, uncoated, with standard oval cup.
JHY-FB-23-230-W-P 2.3 2300 ≥2.8 with spike, coated, with standard oval cup.
JHY-FB-23-230-O-P 2.3 2300 ≥2.8 without spike, coated, with standard oval cup.

Workshop


Certifications
ISO13485 / CE 0197 / SGS / CMDCAS / FDA


Contact Infos
JIUHONG Medical - Jeremy Yang
Phone: +86 186 0258 2990 
ENDOSCOPIC ACCESSORIES SINCE 2003
jiuhongmed.en.made-in-china.com
Medical Instrucments for Clinical! ! Disposable Non-Electric Biopsy Forceps


Others you may also interested




Endeavor for the Development of Chinese Endoscopy Enterprise.

Send your message to this supplier

*From:
*To:
avatar Mr. Ben Xu
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now